beautypg.com

Option led display, For detail, 4 option components – Yaskawa MECHATROLINK-III User Manual

Page 13: Checking led operation

background image

4 Option Components

YASKAWA ELECTRIC TOBP C730600 62B 1000-Series Option SI-ET3 Installation Manual

13

Option LED Display

The MECHATROLINK-III Option has four LEDs that indicate the option card or

communication status.

Checking LED Operation

Table 4 Option LED States

Name

Display Operating Status

Remarks

R/E

Lit in
green

Power supply on

• SI-ET3 has been successfully powered up
• An internal, self-diagnostic check completed in the SI-ET3

Lit in

red

Error

• Error/alarm occured
• Command error occurred (parameter error, phase error,

combination error)

Flashing

in red

SI-ET3 error

Error found during SI-ET3’s self-diagnostic check

Unlit

Power supply off

• The drive has no power
• SI-ET3 is not properly connected to the drive, or SI-ET3 has no

power

• An internal, self-diagnostic error occurred in the SI-ET3

CON

Lit in
green

Connection
established

Established connection

Unlit

Connection
unestablished

Connection with master device is not established

LK1

Lit in
green

Connector CN1
connected

Connector CN1 is connected to other stations

Unlit

Connector CN1
disconnected

Connector CN1 is not connected to other stations (cable not
connected, cable disconnected, other stations not powered up)

LK2

Lit in
green

Connector CN2
connected

Connector CN2 is connected to other stations

Unlit

Connector CN2
disconnected

Connector CN2 is not connected to other stations (cable not
connected, cable disconnected, other stations not powered up)