5 recommissioning the inverter, Recommissioning the inverter, 5recommissioning the inverter – SMA SB 1300TL Service Manual User Manual
Page 22

5
Recommissioning the Inverter
If you have disconnected the inverter from all voltage sources (e.g. for configuration purposes) and
want to recommission it, proceed as follows.
Requirements:
☐ The circuit breaker must be correctly rated.
☐ The inverter must be correctly mounted.
Procedure:
1. Connect the grounding conductor to the inverter
and the enclosure lid.
2. Position the enclosure lid on the enclosure and tighten it using the four screws (torque: 2 Nm).
3. Insert the AC connection socket into the AC pin
connector on the inverter. If necessary, remove
the protective cap beforehand.
4. Connect the DC connectors to the inverter.
5. Seal all unused DC inputs using the DC
connectors and sealing plugs.
☑ The DC connectors snap into place.
6. If an ESS is used, check it for signs of wear:
5 Recommissioning the Inverter
SMA Solar Technology AG
Service Manual
SB13-21TL-SG-en-11
22