12 Technical Data
According to IEC 60721-3-4, Installation Type C, Class 4K4H
According to IEC 60721-3-4, Transport Type E, Class 2K3
12.3 Protective Devices
DC reverse polarity protection
Short-circuit diode
DC disconnect device
Electronic Solar Switch
DC overvoltage protection
Thermally monitored varistors
AC short-circuit current capability
Current control
Grid monitoring
SMA Grid Guard 2.1
Maximum permissible fuse protection
80 A
Earth-fault monitoring
Insulation monitoring: Riso > 280 k Ω
All-pole sensitive residual-current monitoring unit
Available
12.4 Approvals
Country standard,
as per 11/2012
SMC 9000TLRP-10
SMC 10000TLRP-10 SMC 11000TLRP-10
VDE 0126-1-1
✓
✓
✓
VDE-AR-N 4105
✓
✓
✓
UTE C15-712-1
✓
✓
✓
C10/C11
✓
✓
✓
PPDS
✓
✓
✓
RD 1663
✓
✓
✓
RD 661
✓
✓
✓
EN 50438
*
* EN 50438: Does not apply to all national variations of the standard.
✓
✓
✓
GBT19939-2005
✓
✓
✓
CGC GF001-2009
✓
✓
✓
12.5 Climatic Conditions
Extended temperature range
− 25°C … +60°C
Extended humidity range
0% … 100%
Extended air pressure range
70.0 kPa … 106 kPa
Temperature range
− 25°C … +70°C