DC Input
12 Technical Data
12.1 DC/AC
12.1.1 Sunny Mini Central 9000TL with Reactive Power Control
Maximum DC power at cos φ = 1
9,300 W
Maximum input voltage
*
* The maximum open-circuit voltage that can occur at a cell temperature of − 10°C must not exceed the maximum input voltage.
700 V
MPP voltage range
333 V … 500 V
Rated input voltage
350 V
Minimum input voltage
333 V
Start input voltage
400 V
Maximum input current
28 A
Maximum input current per string
**
** Maximum permitted current which may flow via one DC connector
28 A
Number of independent MPP inputs
1
Strings per MPP input
5