5  LED Signals

SMA Solar Technology AG

18

SMC9-11TLRP-BA-en-30

User Manual

5 LED Signals

Designation

Status

Cause and corrective measures

All LEDs

glowing

The inverter is initialising.

flashing

The start-up phase is beginning.
If the DC voltage is very low in the start-up phase, all three
LEDs go out and the start-up phase recommences. If
irradiation is very low, all three LEDs flash. This flashing
indicates a normal operating state. It does not mean that
a fault has occurred.

off

The ESS is not plugged in or the irradiation level is zero.

• Plug in the ESS securely.

Green LED

glowing

Indicates the operating state of the inverter. The specific
status message is shown in the display.

flashing

The DC input voltage is still too low. Once the DC input
voltage is sufficiently high, the inverter goes into
operation.

Red LED

glowing

Earth fault
The specific error or fault message is shown in the display.

• Contact your installer.

flashing

Varistor or string fuse defective
The specific error or fault message is shown in the display.

• Contact your installer.

Yellow LED

glowing

Probably a fault or warning has been issued.
The specific error or fault message is shown in the display.

• Contact your installer.

flashing

Probably a fault or warning has been issued.
The specific error or fault message is shown in the display.

• Contact your installer.