Horizontal installation, Initial installation – Enviro ENVIRO User Manual

Page 20

background image

Initial Installation

QUALIFIED INSTALLERS ONLY

H

ORIZONTAL

I

NSTALLATION

:

1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the

way when the venting system is attached. If this is the case, you may want to adjust the location of

Sealant

Female

Locking

Lugs

Male

Locking

Lugs

Figure 28: Twist-Lock Connection.

Woodscrews

Wall Thimble

Strap

Sheet metal

screws

Fold strap

here

1

1

/

4

"

(3.2cm)

Figure 30: Installing Decorative Wall Thimble.

10"

(254mm)

10"

(254mm)

Figure 29: Wall Framing Hole for

Horizontal Installation.

the appliance.

2. Direct vent pipe and fittings are designed with special twist-lock

connections. Assemble the desired combination of black pipe and

elbows to the appliance adapter with pipe seams oriented towards

the wall or floor, as much out of view as possible.

Place a bead of Mil-Pac on the outer edge of the inner exhaust pipe

(non-flared end). Place a bead of high temperature silicone on the

male edge of the outer pipe. Push the pipe sections completely

together, then twist-lock one section clockwise approximately 1⁄4

turn, until the two sections are fully locked. The female locking

lugs will not be visible from the outside, on black pipe. They may

be located by examining the inside of the female ends as shown in

Figure 28.

Notes:
(a) Twist-lock procedure: four (4) indentations, located on the female

end of the pipes and fittings, are designed to slide straight onto the

male ends of adjacent pipes and fittings, by orienting the four pipe

indentations so they match and slide into the four entry slots on the

male end.
(b) Horizontal runs of vent pipe must be supported every 36” (915mm).

Wall straps are available for this purpose, also when running horizontal

pipe minimum clearances to combustibles must be maintained;

2” (51mm) at top, 11⁄2” (38mm) at sides, 11⁄2” (38mm) at

bottom.
3.
With the pipe attached to the stove in the correct location, mark the

wall for a 10” (25.4cm) x 10” (25.4 cm) square hole (refer to Figure

29). The center of the square hole should match the center line of the

horizontal pipe. Cut and frame the 10” (25.4cm) x 10” (25.4cm) hole in

the exterior wall where the vent will be terminated. Refer to Figure 23

and Table 7. If the wall being

penetrated is constructed of

non-combustible material i.e.

masonry or concrete, a 7”

(17.8cm) hole is acceptable.

4. Position the horizontal vent

termination in the center

of the 10” (25.4cm) x 10”

(25.4cm) hole, and attach

to the exterior wall with

the four screws provided.

Before attaching the vent

termination to the exterior

20