Horizontal installation, Initial installation – Enviro ENVIRO User Manual
Page 20
Initial Installation
QUALIFIED INSTALLERS ONLY
H
ORIZONTAL
I
NSTALLATION
:
1. Set the appliance in the desired location. Check to determine if wall studs or roof rafters are in the
way when the venting system is attached. If this is the case, you may want to adjust the location of
Sealant
Female
Locking
Lugs
Male
Locking
Lugs
Figure 28: Twist-Lock Connection.
Woodscrews
Wall Thimble
Strap
Sheet metal
screws
Fold strap
here
1
1
/
4
"
(3.2cm)
Figure 30: Installing Decorative Wall Thimble.
10"
(254mm)
10"
(254mm)
Figure 29: Wall Framing Hole for
Horizontal Installation.
the appliance.
2. Direct vent pipe and fittings are designed with special twist-lock
connections. Assemble the desired combination of black pipe and
elbows to the appliance adapter with pipe seams oriented towards
the wall or floor, as much out of view as possible.
Place a bead of Mil-Pac on the outer edge of the inner exhaust pipe
(non-flared end). Place a bead of high temperature silicone on the
male edge of the outer pipe. Push the pipe sections completely
together, then twist-lock one section clockwise approximately 1⁄4
turn, until the two sections are fully locked. The female locking
lugs will not be visible from the outside, on black pipe. They may
be located by examining the inside of the female ends as shown in
Figure 28.
Notes:
(a) Twist-lock procedure: four (4) indentations, located on the female
end of the pipes and fittings, are designed to slide straight onto the
male ends of adjacent pipes and fittings, by orienting the four pipe
indentations so they match and slide into the four entry slots on the
male end.
(b) Horizontal runs of vent pipe must be supported every 36” (915mm).
Wall straps are available for this purpose, also when running horizontal
pipe minimum clearances to combustibles must be maintained;
2” (51mm) at top, 11⁄2” (38mm) at sides, 11⁄2” (38mm) at
bottom.
3. With the pipe attached to the stove in the correct location, mark the
wall for a 10” (25.4cm) x 10” (25.4 cm) square hole (refer to Figure
29). The center of the square hole should match the center line of the
horizontal pipe. Cut and frame the 10” (25.4cm) x 10” (25.4cm) hole in
the exterior wall where the vent will be terminated. Refer to Figure 23
and Table 7. If the wall being
penetrated is constructed of
non-combustible material i.e.
masonry or concrete, a 7”
(17.8cm) hole is acceptable.
4. Position the horizontal vent
termination in the center
of the 10” (25.4cm) x 10”
(25.4cm) hole, and attach
to the exterior wall with
the four screws provided.
Before attaching the vent
termination to the exterior
20