beautypg.com

Cycle parameters – HEIDENHAIN TNC 620 (81760x-01) Cycle programming User Manual

Page 402

background image

Touch Probe Cycles: Automatic Workpiece Inspection

16.10 MEASURE RIDGE WIDTH (Cycle 426, DIN/ISO: G426, software

option 17)

16

402

TNC 620 | User's Manual Cycle Programming | 3/2014

Cycle parameters

1st meas. point 1st axis Q263 (absolute):
Coordinate of the first touch point in the reference
axis of the working plane. Input range -99999.9999
to 99999.9999
1st meas. point 2nd axis Q264 (absolute):
Coordinate of the first touch point in the minor axis
of the working plane. Input range -99999.9999 to
99999.9999
2nd meas. point 1st axis Q265 (absolute):
Coordinate of the second touch point in the
reference axis of the working plane. Input range
-99999.9999 to 99999.9999
2nd meas. point 2nd axis Q266 (absolute):
Coordinate of the second touch point in the minor
axis of the working plane. Input range -99999.9999
to 99999.9999
Measuring axis Q272: Axis in the working plane in
which the measurement is to be made:

1

: Reference axis = measuring axis

2

: Minor axis = measuring axis

Measuring height in the touch probe axis Q261
(absolute): Coordinate of the ball tip center (=
touch point) in the touch probe axis in which
the measurement is to be made. Input range
-99999.9999 to 99999.9999
Set-up clearance Q320 (incremental): Additional
distance between measuring point and ball tip.
Q320 is added to

SET_UP (touch probe table). Input

range 0 to 99999.9999
Clearance height Q260 (absolute): Coordinate in
the touch probe axis at which no collision between
touch probe and workpiece (fixtures) can occur.
Input range -99999.9999 to 99999.9999
Nominal length Q311: Nominal value of the length
to be measured. Input range 0 to 99999.9999
Maximum dimension Q288: Maximum permissible
length. Input range 0 to 99999.9999
Minimum dimension Q289: Minimum permissible
length. Input range 0 to 99999.9999
Measuring log Q281: Define whether the TNC
should create a measuring log:

0

: Do not create a measuring log

1

: Create a measuring log: The TNC saves the

log

file TCHPR426.TXT

as standard in the directory

TNC:\.

2

: Interrupt program run and output measuring log

to the TNC screen. Resume program run with NC
Start.

NC blocks

5 TCH PROBE 426 MEASURE RIDGE

WIDTH
Q263=+50

;1ST POINT 1ST AXIS

Q264=+25

;1ST POINT 2ND AXIS

Q265=+50

;2ND POINT 1ST AXIS

Q266=+85

;2ND POINT 2ND AXIS

Q272=2

;MEASURING AXIS

Q261=-5

;MEASURING HEIGHT

Q320=0

;SET-UP CLEARANCE

Q260=+20

;CLEARANCE HEIGHT

Q311=45

;NOMINAL LENGTH

Q288=45

;MAXIMUM DIMENSION

Q289=44.95

;MINIMUM DIMENSION

Q281=1

;MEASURING LOG

Q309=0

;PGM STOP IF ERROR

Q330=0

;TOOL