Cycle run, Please note while programming – HEIDENHAIN TNC 320 (340 55x-04) Cycle programming User Manual
Page 349

HEIDENHAIN TNC 320
349
15.1
1
D
A
TUM IN T
O
UCH PR
OBE AXIS (Cy
c
le 41
7,
DIN/ISO: G41
7
)
15.11 DATUM IN TOUCH PROBE AXIS
(Cycle 417, DIN/ISO: G417)
Cycle run
Touch Probe Cycle 417 measures any coordinate in the touch probe 
axis and defines it as datum. If desired, the TNC can also enter the 
measured coordinate in a datum table or preset table.
1
The TNC positions the touch probe at rapid traverse (value from 
FMAX column) following the positioning logic (see “Executing 
touch probe cycles” on page 283) to the programmed starting 
point 
1
. The TNC offsets the touch probe by the safety clearance
in the positive direction of the touch probe axis.
2
Then the touch probe moves in its own axis to the coordinate 
entered as starting point 
1
and measures the actual position with
a simple probing movement.
3
Finally the TNC returns the touch probe to the clearance height and 
processes the determined datum depending on the cycle 
parameters Q303 and Q305 (see “Saving the calculated datum” 
on page 312) and saves the actual values in the Q parameters 
listed below
Please note while programming:
X
Z
Q260
Parameter number
Meaning
Q160
Actual value of measured point
Before a cycle definition you must have programmed a 
tool call to define the touch probe axis. The TNC then sets 
the datum in this axis.