14.4 BA
SIC R
O
T
A
TION o
v
er T
w
o St
uds (Cy
c
le 402, DIN/ISO: G402)
Cycle parameters
U
1st stud: Center in 1st axis (absolute): Center of the
first stud in the reference axis of the working plane.
Input range –99999.9999 to 99999.9999
U
1st stud: Center in 2nd axis Q269 (absolute): Center
of the first stud in the minor axis of the working plane.
Input range –99999.9999 to 99999.9999
U
Diameter of stud 1 Q313: Approximate diameter of
the 1st stud. Enter a value that is more likely to be too
large than too small. Input range 0 to 99999.9999
U
Measuring height 1 in the probe axis Q261
(absolute): Coordinate of the ball tip center (= touch
point in the touch probe axis) at which stud 1 is to be
measured. Input range –99999.9999 to 99999.9999
U
2nd stud: Center in 1st axis Q270 (absolute): Center
of the second stud in the reference axis of the
working plane. Input range –99999.9999 to
99999.9999
U
2nd stud: Center in 2nd axis Q271 (absolute): Center
of the second stud in the minor axis of the working
plane. Input range –99999.9999 to 99999.9999
U
Diameter of stud 2 Q314: Approximate diameter of
the 2nd stud. Enter a value that is more likely to be
too large than too small. Input range 0 to 99999.9999
U
Measuring height 2 in the probe axis Q315
(absolute): Coordinate of the ball tip center (= touch
point in the touch probe axis) at which stud 2 is to be
measured. Input range –99999.9999 to 99999.9999
U
Setup clearance Q320 (incremental): Additional
distance between measuring point and ball tip. Q320
is added to SET_UP (touch probe table). Input range
0 to 99999.9999
U
Clearance height Q260 (absolute): Coordinate in the
touch probe axis at which no collision between touch
probe and workpiece (fixtures) can occur. Input range
–99999.9999 to 99999.9999
X
Y
Q271
Q269
Q268
Q270
Q313
Q314
X
Z
Q261
Q260
Q315
SET_UP(TCHPROBE.TP)
+
Q320