Environmental criteria, Environmental criteria -7 – Grass Valley PDX 218 User Manual
Page 17
Environmental Criteria
PDX 218 Instruction Manual
1-7
Environmental Criteria
Table 1-4. Environmental Criteria
Characteristics
Description
Operating Temperature
Requirement:
10
°
to 40
°
C (+50
°
to 104
°
F)
Storage Temperature
Requirement:
-40
°
to 60
°
C (-40
°
to 140
°
F)
Operating Altitude
Requirement:
To 10,000 feet (3048 meters)
Supplemental Data:IEC 950 compliant to 2000 meters
Storage Altitude
Requirement:
To 40,000 feet (12,192 meters)
Mechanical Shock
Military Specification: Mil-T-28800D, Class 6 (Non-Operating Only)
Transportation
Requirement:
Qualified under NSTA Test Procedure 1A, Category II (18 inch drop)
Equipment Type
Supplemental Data:Information Technology
Equipment Class
Supplemental Data:Class I
Installation Category
Requirement:
Category II Local level mains, appliances, portable equipment
Pollution Degree
Requirement:
Level 2 operating environment, indoor use only
Humidity
Requirement:
Operating 8% - 90%
Non-Operating 8% - 90%
Maximum Wet Bulb Temperature 29
°
operating
Supplemental Data:Do not operate with visible moisture on the circuit boards