Jumpers, Detail, The control card has several jumper sets – Grass Valley NV5256 v.1.8 User Manual

Page 34: Jumper settings

background image

26

Rev 1.8 • 08 Jul 11

3. Detail

Jumpers

tem). The router control cards will not come out of reset without either an Ethernet connection or
an Ethernet terminator.

(The terminator looks like an RJ-45 plug without the cable.)

Plug a terminator into the Ethernet port of every router control card that does not use Ethernet.

Jumpers

The control card has several jumper sets:

Figure 3-5. EM0374 Router Control Card Jumpers

Table 3-2 describes the jumpers appropriate to the NV5256. Jumpers not listed should be left in the
factory position:

U190

CONSOLE

DIAG

ON

JUMPER

OFF

J29

J28

GND

Rx
Tx

LED7

LED8

LED9

SICK

ACTIVE

HEALTH

PC0436–02

SBUS

10B2

TXD

RXD

J1

J2

SBUS

10B2

J4

SMS7

SBUS

J6

SMS7

SBUS

TIME CODE

110
75
HI Z

J12

J13

AESREF2

J16

AESREF1

Set impedance jumpers (J12, J13, J16) as follows:

• For Phoenix 110W, place both jumpers on the upper 4 pins.
• For BNC 75W place both jumpers on the middle 4 pins.
• For Phoenix Hi-Z, place both jumpers on the bottom 4 pins.
• For BNC Hi-Z, set the left jumper on the bottom 2 pins and

set the right jumper on the middle 2 pins

SBUS

10B2

TXD

RXD

J1

J2

SBUS

10B2

J4

SMS7

SBUS

J6

SMS7

SBUS

J13

AESREF2

J16

AESREF1

SMS7000

Mezzanine Card

(Optional)

Table 3-2. EM0374 Jumpers

Jumper

Settings

J1, J2

Frame-to-frame communication. Leave these jumpers in the 10B2 position. The control card
(and therefore the NV5256) does not support SBus yet.

J4, J6

SMS7000 option. Place the jumpers in the SMS7 position to use a SMS7000 control system
and the Node Bus connectors. Otherwise, leave the jumpers in the SBus position. (SBus is not

supported.)
Note: Using an SMS7000 requires an SMS7000 mezzanine card to be installed.

J13, J16

AES reference termination options. See Figure 3-5 for jumper settings.