3. Detail

Power

Power Supply Alarms

At the lower right portion of the rear of the NV5256 frame is a Phoenix 3-pin connector for power
supply alarms:

The NV5256 has alarm outputs for each power supply installed in the frame. An internal solid-state
relay is provided for each supply. The relay turns on when there is an alarm condition.

Figure 3-3 shows suggested alarm circuit implementations. You can use signalling devices other
than LEDs or in addition to LEDs. For example, you can operate a buzzer or other audible alarm to
warn operators of a potential problem.

Figure 3-3. Power Supply Alarms

CAUTION: The voltage of the external power supply for alarm signalling should not exceed
±30VDC. Resistors should be sized to limit the current through each internal alarm contact to less
than 150mA.

If the load is inductive, the alarm contacts should be protected with a parallel, reverse-biased diode.

Power

The NV5256 has two power supply bays (and two power connectors) to support redundancy. Only
one power supply is actually required.

PS ALARMS

1

2

COM

NORMALLY

CLOSED

E146905

90-130/180-250V~

7.5A/3.75A

50/60Hz

660 WATTS MAX

TO REDUCE THE RISK

OF ELECTRIC SHOCK,

DISCONNECT TWO

POWER SUPPLY CORDS

BEFORE SERVICING.

113-128

8

97-112

7

81-96

6

65-80

5

49-64

4

33-48

3

17-32

2

1-16

1

145-160

10

161-176

11

92

129-144

9

PORTS

13-16

PORT 16

13-16

PORT 16

13-16

PORT 16

13-16

PORT 16

13-16

PORT 16

13-16

PORT 16

13-16

PORT 16

13-16

PORT 16

13-16

PORT 16

13-16

PORT 16

13-16

PORT 16

6

PS Alarm
Connector

1

2

1

2

CO

COM

Customer-supplied relay

contacts NC (and closed

during normal operation)

Extermal Power,

30VDC max, 150mA max

Normally on, the

LEDs turn off to

indicate failure

Normally off, the

LEDs turn on to

indicate failure

External Power

30VDC max, 150mA max

Internal alarm signals

normally clear, controlled

by software

Internal alarm signals

normally clear, controlled

by software