Network connections, Asi connection – Grass Valley K2 ASI Media Client Installation User Manual
Page 23

August 14, 2008
K2 ASI Media Client Installation and Service Manual
23
Connecting System I/O ports
Network Connections
The K2 ASI Media Client operates as a K2 Appliance component into a K2 Shared
Storage. It therefore requires:
• One connection to the K2 Storage System control network: Gig-E port 1 named
Control Connection #1
• One connection to the media (iSCSI) network: Gig-E port 2 named Media
Connection #1
ASI Connection
One ASI input/output card is located at the back of your system. It provides:
• Two input connectors (only one can be used at a time)
• Two output connectors (not used)
Its specifications are detailed in the table below.
The incoming MPEG-2 transport stream should be therefore connected to ASI in 1 or
2.
Item
Description
Frequency offset: accuracy
± 1.0 ppm.
Frequency offset: drift, typical
± 0.5 ppm per year
Connector
BNC, female
Transport stream rate per input
84 Mbps maximum; 1 Mbps minimum
Data format
Supports both burst and packet mode of ASI
format
Packet length
188, 204 bytes
Signal amplitude
880 mV p-p maximum; 200 mV p-p minimum
Termination
75 Ohms
Return loss
- 17 dB, 27 to 270 MHz