Replacing a hard disk – Grass Valley K2 Edge Installation v.4.1.0 User Manual
Page 30

K2 Edge Installation and Service Manual - document version: 4.1
– Page 30
13.3 Replacing a hard disk
CAUTION: To avoid electrostatic discharge, make sure that you are properly grounded.
You do not have to halt or power off the K2 Edge when replacing a single power supply.
Hard disks are hot swappable and redundant.
WARNING: Any instructions in this manual that require opening the equipment cover or
enclosure are for use by qualified service personnel only. To reduce the risk of electric
shock, do not perform any servicing other than that contained in the operating
instructions unless you are qualified to do so.
Hard disks are hot swappable. You do not have to halt and shut down the K2 Edge when
replacing a single disk.
The disk/HDD physical positions on the K2 Edge are:
HDD 1
HDD 3
HDD 5
HDD 0
HDD 2
HDD 4
To replace a hard disk:
Open the front panel.
Push the red button on front of the disk to the right.
Slide the disk out from its bay and remove from the server.
Slide the replacing hard disk into its bay. The hard drive automatically engages with its
connector.
Close the front panel.
To rebuild the disk, contact Support.