beautypg.com

Grass Valley AAP-1741 User Manual

Page 10

background image

GUIDE TO INSTALLATION AND OPERATION

6

| AAP-1741

3.2.1 Status

LED

The status monitor LED is located on the front card-edge of the AAP-1741, and is visible through the front
access door of the DENSITÉ frame. This multi-color LED indicates module status by color, and by
flashing/steady illumination, according to the chart. The chart also indicates fault reporting for this card on the
DENSITÉ frame’s serial and GPI interfaces.



Serial

Report

GPI

Report Green Yellow Red

Flashing

Red

Flashing

Yellow

Card system error

›

›

-

Not expected reference Error

›

›

-

Reference error

›

›

NSD CH 1 to 4 Analog input

›

›

-

NSD CH 9 to 16 (Ext.CH 1/8 or 9/16)

›

›

-

OVERLOAD CH 1 to 4 analog inputs

›

›

OVERLOAD CH 1 to 16 processing

›

›

-

OVERLOAD analog outputs 1 to 4

›

Any TONE activated

›

›

-

Any output Mute

›

›

-

User attention

-

-

-

-

-

-

Yes

Rear panel error

-

-

-

-

-

Yes

-

FPGA error

-

-

-

-

-

Yes

›

: Factory default.

Note: The non-requested message posting to an alarm status can only be accessed by the
communication protocol (serial port)

NOTE:

A “Flashing Yellow” Status LED indicates that the SELECT button on the front panel has been

pushed.