8950DAC Instruction Manual

13

Power Up

Table 3. Input and Output Conditions

Input Signal

Standard Detection

LED State

Output Signal

No signal

Auto mode

VID PRES off
625 off
525 off
MAN mode off
FAULT flashing

0 V ±20 mV

No signal

Manual mode 525

VID PRES off
625 off
525 on
MAN mode on
FAULT flashing

0 V ±20 mV

No signal

Manual mode 625

VID PRES off
625 on
525 off
MAN mode on
FAULT flashing

0 V ±20 mV

Signal present 525

Auto mode

VID PRES on
625 off
525 on
MAN mode off
FAULT off

Valid video output

Signal present 625

Auto mode

VID PRES on
625 on
525 off
MAN mode off
FAULT off

Valid video output

Signal present 525

Manual 525

VID PRES on
625 off
525 on
MAN mode on
FAULT off

Valid video output

Signal present 625

Manual 525

VID PRES on
625 off
525 flashing
MAN mode on
FAULT off

Invalid video output

Signal present 525

Manual 625

VID PRES on
625 flashing
525 off
MAN mode on
FAULT off

Invalid video output

Signal present 625

Manual 625

VID PRES on
625 on
525 off
MAN mode on
FAULT off

Valid video output