8950DAC Instruction Manual

11

Power Up

Power Up

The various front LED indicators and configuration switches are illustrated
in

Figure 4

. Upon power-up, the green PWR LED should light and the

yellow CONF LED should illuminate for the duration of module initializa-
tion.

Operation Indicator LEDs

With factory default configuration and a valid input signal connected, the
green PWR LED, and one of the yellow signal standard LEDs (525 or 625)
should illuminate (refer to

Table 2 on page 12

to see the possible operating

indicator combinations).

Video input presence is indicated by an illuminated VID PRES LED and the
appropriate 525 or 625 LED (indicating a 525-line or 625-line input signal
has been detected). The MAN LED, when on, indicates that manual stan-
dard selection is enabled.

Figure 4. LEDs and Configuration Switches

16-position
Rotary switch

Momentary toggle switch

525 – Yellow LED on indicates 525 mode input

PWR – Green LED on indicates power OK

FAULT – Red LED is off during normal operation

Ejector Tab

COMM (Yellow)

CONF (Yellow)

MAN MODE – Yellow LED on indicates manual input selection

625 – Yellow LED on indicates 625 mode input

VID PRES – Green LED on indicates a valid video input signal is present

Module Configuration Switches and LED

GND

2nd Function
(Yellow)

0604_06