Resetting the system of an oap module – H3C Technologies H3C WX3000E Series Wireless Switches User Manual
Page 10
3
Resetting the system of an OAP module
If the operating system is not working properly or is under other anomalies (for example, the system does
not respond), you can reset the system of an OAP module with the following command, which is equal
to resetting the OAP module by pressing the reset button on the OAP module.
An OAP module has an independent CPU; therefore, the device can still recognize and control the OAP
module after you reset the OAP system.
To reset the system of an OAP module:
Task Command
Remarks
Reset the system of an OAP
module.
oap reboot slot slot-number
Available in user view
CAUTION:
Resetting of the OAP module may cause data loss and service interruption. Before resetting the OAP
module, save the configurations of the OAP module operating system and shut it down to avoid service
interruption and hardware data loss.
- H3C WX5500E Series Access Controllers H3C WX3500E Series Access Controllers H3C WX2500E Series Access Controllers H3C WX6000 Series Access Controllers H3C WX5000 Series Access Controllers H3C LSWM1WCM10 Access Controller Module H3C LSUM3WCMD0 Access Controller Module H3C LSUM1WCME0 Access Controller Module H3C LSWM1WCM20 Access Controller Module H3C LSQM1WCMB0 Access Controller Module H3C LSRM1WCM2A1 Access Controller Module H3C LSBM1WCM2A0 Access Controller Module