Page 11

background image

4

Item Requirements

Yes No

Temperature

0°C to 40°C (32°F to 104°F)

Relative humidity

5% to 90% (noncondensing)

Cleanness Dust

concentration

≤ 3 × 10

4

particles/m

3

ESD prevention

The equipment and floor are correctly grounded.

The equipment room is dust-controlled.

Humidity and temperature are maintained at

acceptable levels.

Wear an ESD wrist strap when inspecting or handling

a circuit board.

EMI prevention

Take measures to protect the power system from the
power grid system.

Keep the protection ground of the router as far away

from the grounding device or lightning protection
grounding device as possible.

Keep the router far away from radio transmitters, radar,

and high-frequency or high-voltage devices.

Use electromagnetic shielding when necessary.

Lightning protection

The grounding cable of the chassis is grounded

correctly.

The grounding terminal of the AC power receptacle is

grounded correctly.

A port lightning arrester is installed. (Optional.)

A power lightning arrester is installed. (Optional.)

A signal lightning arrester is installed at the input end

of an external signal cable. (Optional.)

Electricity safety

Install a UPS.

In case of emergency during operation, switch off the

external power switch.

Workbench

The workbench is stable.

The workbench is grounded correctly.

Safety
precautions

The router is far away from any sources of heat or moisture.

The emergency power switch in the equipment room is identified and

accessible.

Tools

Installation accessories supplied with the router are ready.

User-supplied tools are ready.

Reference

Documents shipped with the router are available.

Online documents are available.