Configuring an e1 channel – H3C Technologies H3C SR8800 User Manual

Page 42

background image

35

Step Command

Remarks

8.

Configure the SOH and

higher-order path overhead
bytes.

flag { c2 path-number c2-value

| s1 s1-value | s1s0
path-number s1s0-value
}

flag { j0 | j1 path-number }

{ sdh | sonet } flag-value

Optional.

The default value of c2 is 0x02
(hexadecimal) and s1 is 0x0f

(hexadecimal). The default

value of s1s0 is 0x0 for SONET

and 0x2 for SDH.

For SONET frames, the default

value of j0 is 0x01 and that of

j1 is null; for SDH frames, the
initial values (for example, the

value when the router is initially

powered on) of both j0 and j1
are SR8800, and the values

change to null after a change in

the framing format.

9.

Restore the default settings.

default

Optional.

10.

Shut down the CPOS

interface.

shutdown

Optional.
By default, a CPOS interface is up.

11.

Bring up the CPOS interface. undo shutdown

Optional.
By default, a CPOS interface is up.

12.

Configure the signal degrade

(SD) threshold and the signal
fail (SF) threshold.

threshold { sd | sf } value

Optional.
By default, the SD alarm threshold

is 10e-6; the SF alarm threshold is
10e-4 for PIC-CLF2G8L and

PIC-CLF4G8L CPOS sub-cards and

10e-3 for other types of CPOS
sub-cards.

13.

Configure E1/T1/E3/T3
channel attributes.

See “

Configuring an E1

channel

.”

See “

Configuring a T1

channel

.”

See “

Configuring an E3

channel

.”

See “

Configuring a T3

channel

.”

Optional.

NOTE:

E1 configuration is supported on the CPOS(E) interface module but T1 configuration is supported on the
CPOS (T) interface module.

If no cable is connected to a physical interface, shut down the interface with the shutdown command to
prevent anomalies caused by interference.

Use the shutdown command with caution, because once an interface is shut down, it stops operating.

Configuring an E1 channel

To configure an E1 channel: