Signals menu – Ensemble Designs 7465 Sync Changeover Switch User Manual
Page 19

www.ensembledesigns.com
Page 19
7465 Sync Changeover Switch and 9465 3G Sync Changeover Switch
Signals Menu
The Signals menu shown below displays the status of each of the Primary and Secondary A, B and C
channels. Signal status is reported as the following for each channel signal type:
• Pri A Status – Status indicators for SDI serial digital reference are Not Tested, Not Locked or
Normal.
• Pri B Status – Status indicators for Analog Video, AES audio and Tri-Level Sync reference are
Not Tested, No Signal, Low Level, Normal, Overload or Error.
• Pri C Status – Status indicators for Analog Video, AES audio and Tri-Level Sync reference are
Not Tested, No Signal, Low Level, Normal, Overload or Error.
• Sec A Status – Status indicators for SDI serial digital reference are Not Tested, Not Locked or
Normal.
• Sec B Status – Status indicators for Analog Video, AES audio and Tri-Level Sync reference are
Not Tested, No Signal, Low Level, Normal, Overload or Error.
• Sec C Status – Status indicators for Analog Video, AES audio and Tri-Level Sync reference are
Not Tested, No Signal, Low Level, Normal, Overload or Error.