7465 and 9465 parameter table – Ensemble Designs 7465 Sync Changeover Switch User Manual
Page 14

www.ensembledesigns.com
Page 14
7465 Sync Changeover Switch and 9465 3G Sync Changeover Switch
CONTROL
LOCAL
REMOTE
DEFAULT
Primary
Selected with Control
Switch
Selects Primary
Selected
Secondary
Selected with Control
Switch
Selects Secondary
Deselected
Auto
Selected with Control
Switch
Selects Auto
Selected
Auto Reset
Switch 8:
On (left)
Off (right)
On
Off
On
Reset Time
5 seconds
0 - 60 seconds
15 seconds
Ch A Mode
Switch 1
A Enable (left)
A Disable (right)
Off
Serial
Serial
Ch B Mode
Switch 3
B Enable (left)
B Disable (right)
Switch 4
Vid (left)
AES (right)
Off
Composite
AES
Tri-Level
LTC
Composite
Ch C Mode
Switch 5
C Enable (left)
C Disable (right)
Switch 6
Vid (left)
AES (right)
Off
Composite
AES
Tri-Level
LTC
Composite
Gang Enable
Off
Off
Master
Slave
Off
Slave Select
1
1
2
3
1
Slave Enable
Disabled
Enabled
Disabled
Disabled
Frame Adr
1
1 - 1000
1
Slot Number
1
1 - 10
1
7465 and 9465 Parameter Table