beautypg.com

I technical details, Safety instructions, I.1 types i.2 cable entry and assembling – Eneo VHM/ECLKA-W User Manual

Page 12: I.3 common technical details

background image

I Technical details

The VHM housing series is designed mainly for cameras
with fixed focus and most /3" - /" zoom lenses.
4-stage height adjustment of the camera for mounting
is possible using the rack-support (camera tray).
The accessories listed in section VI are for assembly
completion and making installation easier.

Safety instructions

The following instructions are for your own safety
and should be observed without fail:
• Please read the safety notes and following

installation instructions before connecting the unit.

• Keep the operating manual in a safe place for later

reference.

• The unit is only intended for permanent connection
to the power supply circuit.
• Only connect the device to a suitable electrical

source.

• Never operate the housing beyond its technical

specification.

• Pay attention to safety when laying the connection

cable and lay cable so that it cannot be buckled,

damaged, or subjected to loads or damp.

• If moisture has penetrated the device, do not switch

on under any circumstances.

In this case, have the device checked by a qualified

service technician.

• An easily accessible all-pole disconnecting
device with 3mm minimum contact gap width
is to be installed near the unit so that it can be
disconnected for service work. Earthing must be
low-resistance in compliance with DIN VDE 0100.
• The housing may only be opened by authorized

personnel. Connection work must be carried out

by a qualified technician.

• The warranty becomes void if repairs are undertaken

by unauthorized persons.

• Before opening the device, the mains voltage must

be switched off.

• Only DIN VDE 0860 and DIN VDE 0805 tested

components/tools are to be used for installation.

Installation is to be carried out in compliance with

the installation instructions and under observation

of all applicable standard regulations.

• Operate the device only at a temperature range of

-30°C to +60°C and at a humidity of max. 90%.

• The device must be protected from extreme heat,

dust, moisture and vibration.

• Do not place any heavy items on the device.
• The installer is responsible for maintaining the IP 66

protection system.

• Stainless screws must be used when installing the

unit outdoors.

• Only use original replacement parts from

Videor E. Hartig GmbH.

I.1 Types

I.2 Cable entry and assembling

Economy (EC): 3 glands (M6x.5)
Standard (ST):

same as for EC, but with inside

central plug connection

I.3 Common technical details

Type

Description

Execution

VHM/EC

Weatherproof housing

Economy

VHM/ST

Weatherproof housing

Standard

VHM/DP-EC

Dustproof housing

Economy

VHM/DP-ST

Dustproof housing

Standard

Max. input voltage

50V / 50Hz

Max. input current

300mA / AC

Screen heater

0-50V, 7W
-30V, 7W

Temperature range

-30° to + 60°C
(with screen heater)

Noise generation

< 70dBa

Protection class

IP66

This manual is related to the following products: