beautypg.com

9 alarm – Eneo EDC-4222B User Manual

Page 39

background image

6. Press and hold down the CTRL key while controlling the camera direction and zoom with

the Joystick. The dome will be automatically recorded until you release the CTRL key. Or
press IRIS Open then the “CTRL” displays. Move the position and the zoom position. Press

IRIS Close then the “CTRL” disappears.

7. Select Save and Exit and push the Joystick to the right. Press ESC to exit the program

without saving.

Note : Press the HOME key at any programmed position to delete the pattern.

Note : If total recording time reaches 500 seconds, it will automatically stop for a moment.

3.9 Alarm

No : Alarm input number
Priority : The lower number has higher priority. (1-8)
Function : Stored function number to be called by alarm.
In : NO/NC - normally open /closed OFF - ignore
Out : OUT1~OUT4 - Relay out 1,2,3,4, OFF - No output.
Hold : Alarm will be held for programmed time (03 to 99 seconds)

Latch
: ON - Shows all alarms including past alarm.

33