checking the sYsteM Before use

Switch the device on and check that the LED’s are working correctly:
Move switch A (Control Panel) upward;
In this way Bravo DSB switches on and automatically executes self-diagnostics of the device,
causing the LED’s of the regulation valve simulator (O), the

PRESS

function LED (M) and the

LOW BATT

signal to flash.

6.1

Tests on valve-control signals

At this point, test the Bravo components, checking that each action of the computer causes the
corresponding LED on the control panel to light up.

coMPonent

BehAViour of Led

on BrAVo dsB

Action

GENERAL VALVE

Red LED

Valve opening command

Green LED

Valve closing command

LED off

Not connected command

REGULATION VALVE

Red LED

Increase in pressure command

Green LED

Decrease in pressure command

LED off

No command or not connected

SECTION VALVES

Red LED

Valve opening command

Green LED

Valve closing command

LED off

Not connected command

FOAM MARKER

Green

L LED

Left side selection of foam marker

Green

r LED

Right side selection of foam marker

Tab. 5