Installation
Mounting Location
1. Select a convenient, dry, mounting location for the water-
resistant Gateway, a minimum of 1m (3') from the PC (see
Figure 1).
2. Hold the Gateway at the selected location and mark the position
of the screw holes. If the box will be mounted on a vertical
surface, face the cables downward to avoid water seeping into
the box.
3. At the marked locations, drill the holes for the screws. Do not
fasten the Gateway in place at this time.
NMEA 2000 Network Cable
Route the network cable from the Gateway to the network
backbone cable. Do not connect the cable or fasten it in place at
this time.
PC Cable
Route the PC cable from the Gateway to the PC. Do not connect
the cable or fasten it in place at this time.
Completing the Installation
1. Fasten the Gateway in place with the screws supplied.
2. Plug the NMEA 2000 network cable into the network.
3. Plug the PC cable into the PC.
4. Fasten all the cables in place. Coil any excess cable(s) and
secure it with cable ties to prevent damage.
Operation
LED Status Lights
There are two, green, LED status lights that will flash when the
Gateway is operating. One LED monitors the NMEA 2000 bus
and the other monitors the USB port.
Parts
Obtain parts from your instrument manufacturer or marine dealer.
Gemeco
Tel: 803.693.0777
(USA)
Fax: 803.693.0477
email: [email protected]
Airmar EMEA
Tel: +33.(0)2.23.52.06.48
(Europe, Middle East, Africa)
Fax: +33.(0)2.23.52.06.49
email: [email protected]
Figure 1. Connecting
(WeatherStation® Instrument shown)
Copyright © 2008 - 2011 Airmar Technology Corp.
network
backbone
cable
Weather-
Station
network
cable
PC
cable