beautypg.com

Introduction specifications – Empire Comfort Systems CHBR-16-3 User Manual

Page 5

background image

Page 5

16934-3-0806

Qualified Installing Agency

Installation and replacement of gas piping, gas utilization equipment

or accessories and repair and servicing of equipment shall be

performed only by a qualified agency. The term "qualified agency"

means any individual, firm, corporation, or company that either in

person or through a representative is engaged in and is responsible

for (a) the installation, testing, or replacement of gas piping or (b) the

connection, installation, testing, repair, or servicing of equipment;

that is experienced in such work; that is familiar with all precautions

required, and that has complied with all the requirements of the

authority having jurisdiction.

State of Massachusetts: The installation must be made by

a licensed plumber or gas fitter in the Commonwealth of

Massachusetts.
Sellers of unvented propane or natural gas-fired supplemental

room heaters shall provide to each purchaser a copy of 527 CMR

30 upon sale of the unit.
In the State of Massachusetts the CHBR-16 must be secured

to the floor.

The installation must conform with local codes or, in the absence

of local codes, with the National Fuel Gas Code, ANSI Z223.1.*

*Available from the American National Standards Institute, Inc. 11 West 42nd St.,

New York, N.Y. 10018.

IMPORTANT: Read all instructions carefully before starting

installation. Failure to follow these installation instructions may

result in a possible fire hazard and will void the warranty.
Save this manual for future reference.
Please read this manual before installing and using the

appliance.
Instructions to Installer

1. Installer must leave instruction manual with owner after

installation.

2. Installer must have owner fill out and mail warranty card supplied

with unvented room heater.

3. Installer should show owner how to start and operate unvented

room heater.

Always consult your local Building Department regarding

regulations, codes or ordinances which apply to the installation

of an unvented room heater.
This appliance may be installed in an aftermarket* manufactured

(mobile) home, where not prohibited by state or local codes.
*Aftermarket: Completion of sale, not for purpose of resale, from

the manufacturer.

This appliance is only for use with the type of gas indicated on

the rating plate. This appliance is not convertible for use with

other gases.
Any alteration of the original design, installed other than as shown

in these instructions or use with a type of gas not shown on the

rating plate is the responsibility of the person and company making

the change.

INTRODUCTION

SPECIFICATIONS

Manifold Pressure

Natural Gas

Propan Gas

Regulator pressure setting 3.5" W.C.

Regulator pressure setting

10.0" W.C.

Gas inlet pressure

Max. 10.5" W.C. Gas inlet pressure

Max 13.0" W.C.

Min. 5.0" W.C.

Min. 11.0" W.C.

Model

CHBR-16

Input Maximum Btu/Hr

Minimum Btu/Hr

20,000

14,000

Height

49"

Width

23"

Gas Inlet

3/8"

ACCESSORIES

Product

No.

Description

CHG-VF

Antique Green Chimenea

CHR-VF

Terra Cotta Red Chimenea

FRBC-1

Battery Operated Remote Control

FRBTC-1

Battery Operated Remote Control with Thermo-

stat

FREC-1

Electri Remote Control

FWS-1

Wall Switch