Troubleshooting – Empire Comfort Systems CHBR-16-3 User Manual

Page 17

background image

Page 17

16934-3-0806

If the gas quality is bad, your pilot may not stay lit, the burners may produce soot and the heater may backfire when lit. If the gas quality or pressure is

low, contact your local gas supplier immediately.

1. When ignitor button is pressed, there is no spark at ODS/

pilot.

a. Ignitor electrode positioned wrong - Replace pilot.

b. Ignitor electrode is broken - Replace pilot.

c. Ignitor electrode not connected to ignitor cable - Reconnect

ignitor cable.

d. Ignitor cable pinched or wet. Keep ignitor cable dry - Free

ignitor cable if pinched by any metal or tubing.

e. Broken ignitor cable - Replace ignitor cable.

2. Appliance produces unwanted odors.

a. Appliance burning vapors from paint, hair spray, glues,

etc. - Ventilate room. Stop using odor causing products

while heater is running.

b. Gas leak - Locate and correct all leaks.

3. Appliance shuts off during use. (Pilot and main burner

are off.)

a. Not enough fresh air is available for ODS/pilot to operate

- Open window and/or door for ventilation.

b. Low line pressure - Contact local gas company.

c. ODS/pilot is partially clogged - Clean ODS/pilot.

d. Defective thermocouple - Replace pilot.

4. Appliance shuts off during use. (Pilot stays on.)

a. Low line pressure - Check line pressure to the valve.

b. Defective thermopile - Check pilot flame, check wire

connections, output should be a minimum of 325 millivolts

across. TH/TP and TP terminals with ON/OFF switch

off.

5. Gas odor even when control knob is in OFF position.

a. Gas leak - Locate and correct all leaks.

b. Control valve defective - Replace control valve.

6. When ignitor button is pressed, there is spark at ODS/pilot,

but no ignition.

a. Gas supply turned off or manual shutoff valve closed

- Turn on gas supply or open manual shutoff valve.

b. Control knob not in PILOT position - Turn control knob

to PILOT position.

c. Control knob not pressed in while in PILOT position

- Press in control knob while in PILOT position.

d. Air in gas lines when installed - Continue holding down

control knob. Repeat igniting operation until air is

removed.

e. ODS/pilot is clogged - Replace ODS/pilot assembly or

have it serviced.

g. Gas regulator setting is not correct - Replace gas

regulator.

7. ODS/pilot lights but flame goes out when control knob is

released.

a. Control knob not fully pressed in - Press in control knob

fully.

b. Control knob not pressed in long enough - After ODS/pilot

lights, keep control knob pressed in 30 seconds.

c. Manual Shutoff valve not fully open - Fully open manual

shutoff valve.

d. Thermocouple connection loose at control valve - Hand

tighten until snug, then tighten 1/4 turn more.

e. Pilot flame not touching thermocouple, which allows

thermocouple to cool, causing pilot flame to go out. This

problem could be caused by either low gas pressure or

dirty or partially clogged ODS/pilot - Contact local gas

company.

f. Control valve damaged - Replace control valve.

8. Burner does not light after ODS/pilot is lit.

a. Burner orifice clogged - Clean burner or replace main

burner orifice.

b. Burner orifice diameter is too small - Replace burner

orifice.

c. Inlet gas pressure is too low - Contact qualified service

person.

9. If burning at main burner orifice occurs (a loud, roaring

blow torch noise).

a. You must turn off burner assembly and contact a qualified

service person.

b. Manifold pressure is too low - Contact local gas

company.

c. Burner orifice clogged - Clean burner or replace burner

orifice.

10. Logs appear to smoke after initial operation.

a. Vapors from paint or curing process of logs - Problem

will stop after a few hours of operation. Open a window

for the first few hours.

Log heater is intended to be smokeless. Turn OFF heater

and call qualified service person.

11. Heater produces a whistling noise when main burner is

lit.

a. Turning control knob to HIGH position when main burner

is cold - Turn control knob to LOW position and let warm

up for a minute.

b. Air in gas line - Operate burner until air is removed from

line. Have gas line checked by local gas company.

c. Dirty or partially clogged burner orifice - Clean burner or

replace burner orifice.

12. No gas to pilot.

a. LP-regulator shut down due to inlet pressure too high -

Verify LP tank regulator is installed and set at 11" to 13"

w.c.

TROUBLESHOOTING

SYMPTOMS - POSSIBLE CAUSES AND CORRECTION

S

Turn appliance OFF and allow to cool before servicing. Only a qualified service person should service and repair the heater.