2 technical specifications – AEC AG Auger Series Granulator User Manual
Page 33
6.5” Granulators
Chapter 7: Appendix
32 of 35
7-2 Technical Specifications
Features
Model
Throat Size
Cutting Circle
Diameter
Throughput
Approximate
Weight
6 x 8
6” x 8”
(15 x 20 cm)
6” (152 mm)
175 lbs./hr.
(79 kg.)
650 lbs.
(296 kg.)
8 x 12
8” x 12”
(20 x 30 cm)
8” (203 mm)
250 lbs./hr.
(113 kg.)
1300 lbs.
(591 kg.)
12 x 16
12” x 16”
(30 x 40 cm)
12” (305 mm)
450 lbs./hr.
(204 kg.)
2400 lbs.
(1090 kg.)
Specifications
Standard
Standard Options
Infeed
Hopper, one-piece reversed flight
auger
Increased or decreased auger length,
adjustable fifth wheel at auger end
Cutting
Chamber
Slant cut shearing design with screen
drawer and hinged lid
Hardface welding (8 x 12 and 12 x
16 models only)
Rotor
D2
Carbide coating, Hardface welding
(6 x8 and 8 x 12 models only)
Rotor Knives
3
Bed Knives
2
Screen
Corten reversible screen, 5/16”
Carbide coating, 1/8”, 3/16”, 1/4”
Base
Two swivel casters, two fixed casters
3”, 4”, and 6” base leg extensions
Discharge
Bin
Oversized collection bin, Pneumatic
evacuation system
Motor
6 x 8: 3HP, 5HP
8 x 12: 5HP, 7.5 HP
12 x 16: 10 HP, 15HP
Drive Parts
Heavy-duty auger chain drive
Electrical
Components
Fused disconnect, NEMA 12
magenetic across-the-line starter
control
Controls
208, 230, 460 or 575 V
Labels
English
Accessories
Optional Features
Auger Trough Safety Guard. A fabricated guard that bolts to the auger trough frame,
surrounding the feed opening, and providing adequate guarding in accordance with OSHA
2206. This feature is required when an auger granulator is positioned away from the process
machine for hand-loading purposes, or when using a mechanical loading device.
Fan System. A pneumatic take-off system that recycles granulate from the granulator
discharge bin to the process machine, hopper, or to a storage container. The system consists
of an impeller blower, driven by an appropriately sized 3 phase, 60cycle motor, and a cyclone
air separator. The blower and motor are usually mounted on the granulator with control in the
main panel. The cyclone air separator and all piping is assembled and fixed by the customer
to suit individual requirements.