Large Dehumidifying Dryers
Controls
55
4. Press “Dryer Menu” to return to the dryer menu display.
5. Press “Help” to access the help menu display.
Dew Point Setup
1. Press “High Alarm Setting” to change the value for the high dew point alarm limit.
2. Press the “Switch on Time or Dew Point” button to cause the dryer to either
immediately switch beds following the completion of a regeneration cycle (Switch on
Time) or switch beds when either the dew point exceeds a pre-set limit or a
maximum on-line time has been reached (Switch on Dew Point).
When the switch on dew point option is selected,
3. Press “Bed Switch Point” to change the dew point value at which the beds will switch
sides.
4. Press “Bed Online Time” to change the time a bed is allowed to be online even if the
dew point is low.
Auto-Start Timer Option Setup
The AP1+ includes a 7 day programmable timer that can be used to start and stop the dryer
on a repeating schedule.
1. Press “ON TIME” or “OFF TIME” to enter the time of day in 24 hour format for
each start and stop event. Midnight, 00:00, is treated as a skip event in order to allow
event durations that span multiple days.
2. Press the “Auto Start Option” button to allow dryer start and stop events to occur as
scheduled “Option ON” or to temporarily disable all automatic start and stop events
“Option OFF”.