Westermo FD-80 User Manual
Page 14

14
6630-2281
6.4.6 Telnet configuration; Ethernet slave,
point to point with continuously transfer mode
Continuous transfer mode between two FD-80s by setting FD-80
(P) in box to box mode, one as master port and one as slave port.
FD-80; Master port
1. Set the IP-address of this FD-80 to
mask and IP-address of the Gateway, select SETUP System > Setup TCP/IP.
2. Set the Port of the FD-80 Slave port to , select SETUP Port 0 (Serial) >
TCP/IP Mode > Box to Box > Slave Port.
3. Set the IP-address of the FD-80 slave port to
Port 0 (Serial) > TCP/IP Mode > Box to Box > IP-Address.
4. Save all changes before closing the Telnet connection, select SAVE Setup.
FD-80; Slave port
1. Set the IP-address of this FD-80 to
mask and IP-address of the Gateway, select SETUP System > Setup TCP/IP.
2. Check that the FD-80 port is set to standard TCP/IP mode, to
SETUP Port 0 (Serial) > Port State > Connection State. If the port is not
set to FREE, the FD-80 can be set to standard TCP/IP mode, select SETUP Port 0
(Serial) > Port State > Clear Port Mode.
3. Save all changes before closing the Telnet connection, select SAVE Setup.
6.4.7 Telnet configuration; Ethernet slave,
point to point with addressed mode
This FD-80 is one slave in a Master-Slave network by setting the FD-80 (P)
in IP Bus mode.
1. Set the IP-address of this FD-80 to
mask and IP-address of the Gateway, select SETUP System > Setup TCP/IP.
2. Set the IP-address of the Master to
(Serial) > TCP/IP Mode > IP Bus Mode > Slave: Master IP.
3. Save all changes before closing the Telnet connection, select SAVE Setup.
6.4.8 Telnet configuration; Ethernet master,
addressed mode
This FD-80 is made the master in a Master-Slave network by setting the FD-80 (A)
in IP Bus mode.
1. Set IP-address of this FD-80 to
mask and IP-address of the Gateway, select SETUP System > Setup TCP/IP.
2. Set the network address of the subnet in which the Master and Slaves are located to
Mode > Master: Subnet IP.
3. Save all changes before closing the Telnet connection, select SAVE Setup.