Users manual, Mc100 – Watson-Marlow MC100 User Manual
Page 33

Users Manual
MC100
MC100 Users Manual Profibus DP - rev 4
Rev. 4
Page 33 of 40
8.2 Warnings handling
All warnings are cleared automatically, when data within limits are received via FB, or with clear-bit:
MC100 command B1.4
In warning 08-13 by the phrase individual pumps, means “real” connected pumps and pump 0 means
the pseudo pump, which holds common parameters in parallel and serial mode
8.2.1 Warnings
Warning no.
Warning description
Action
0
No pending warnings
1
Fill volume out of range
Attempt to set parameter that is
outside limits.
Set new parameter.
2
Tube number is not in table
3
Speed setting is out of range
4
Acceleration setting is out of range
5
Reverse setting is out of range
6
Density setting is out of range
7
Calibration is out of range
8
Common calibration in parallel
Calibration attempt for Pump 0.
Calibrate pumps individually.
9
Individual calibration in serial
Calibration attempt for individual
pump, calibrate pump 0 only
10
Attempt to set common parameters to
individual pump in serial mode
Set parameters via pump 0
(fictive common pump) or clear
warning.
11
Attempt to calibrate pump 0 (fictive common
pump) in individual mode
Clear by calibrating physical
connected pumps (1 to 15).