Users manual, Mc100, 1 reading strings – Watson-Marlow MC100 User Manual

Page 31

background image

Users Manual

MC100

MC100 Users Manual Profibus DP - rev 4

Rev. 4

Page 31 of 40



7.3.2.1.1 Reading strings:


Set the request bit for receiving text strings in DW10 (bit 15) and the required text number in DW10 bit
0 – 4.

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

1

0

0

0

0

0

0

0

-

-

-

N4

N3

N2

N1

N0


Setting the number in DW10 and the PS bit in DW11 will read the string i DW12-25 status:

Example:
In the following “Control” means data from the PLC to the MC100 and “Status” means data from
MC100 to the PLC.

Request the FMB version as text

Step 1: Set the request bit for text string (bit 15) and the text number in DW10 Control

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

1

0

0

0

0

0

0

0

-

-

-

0

0

0

0

1


Step 2: Receive the text string in DW 12 to 21 Status.
“MC100 FBM Ver. x.yy.z”