Users manual, Mc100 – Watson-Marlow MC100 User Manual
Page 18

Users Manual
MC100
MC100 Users Manual Profibus DP - rev 4
Rev. 4
Page 18 of 40
When the above data package is received by the MC100 it acknowledges by returning a new data
package (MC100
PLC). The structure of the returned data package is different if the return data are
requested as a data communication or a text string. This is selected in data word 10 as described in
section 7.2.2
If the PLC has requested a data communication:
Data
word no
Content
Described in section
0
MC100 control bits
7.1.3
1
Control pump 1 and 2
7.1.5
2
Control pump 3 and 4
7.1.5
3
Control pump 5 and 6
7.1.5
4
Control pump 7 and 8
7.1.5
5
Control pump 9 and 10
7.1.5
6
Control pump 11 and 12
7.1.5
8
Control pump 13 and 14
7.1.5
9
Control pump 15 and 16
7.1.5
10
Header for word 12 to 21
7.2.3
11
For future use
7.2.4
12
Volume data for the pump selected in word 0 – part 1
7.2.1
13
Volume data for the pump selected in word 0 – part 2
7.2.1
14
Tube used in the pump selected in word 0
7.2.1
15
Speed data for the pump selected in word 0
7.2.1
16
Acceleration data for the pump selected in word 0
7.2.1
17
Reverse data for the pump selected in word 0
7.2.1
18
Density data for the pump selected in word 0 – part 1
7.2.1
19
Density data for the pump selected in word 0 – part 2
7.2.1
20
Calibration data for the pump selected in word 0 – part 1
7.2.1
21
Calibration data for the pump selected in word 0 – part 2
7.2.1
22
Alarm and warning
7.2.5