6 stop filling, 7 used as a pump, 8 used with a bottle handling system – Watson-Marlow PF22 User Manual
Page 25: Operators manual

Operators Manual
PF22
PF22 OM EN 74-132-005 v1.02.doc
Version: 1.02
Page 25 of 34
6.6 Stop filling
When PF22 has completed the number of fills asked for in F6: it will stop automatically. If
pressed again, PF22 will complete the programmed number of fills once more.
If you want to stop the filling before the programmed number has been completed, press
and PF22 will stop after completing the filling in progress.
The filling series can be completed by pressing
If you want to stop IMMEDIATELY, such as in the middle of a fill, press
will stop immediately.
The filling series can be completed by pressing
included.
6.7 Used as a pump
PF22 can also be used as a pump.
In this case only velocity should be entered.
Start the pumping by pressing
PF22 will start and run the required number of revolutions per minute.
PF22 will pump at this velocity until stopped by pressing
6.8 Used with a bottle handling system
PF22 can also be used together with a bottle handling system like FlexFeed 20 from Flexicon.
When PF22 is integrated in an automatic bottle handling system, it is important to observe the
following:
The batch size in case of running with a bottle handling system must be set to 1.
The PF22 should be in “dispense mode” before starting the fill sequence.
The Go signal which activates filling should be generated by the bottle handling system.
The Go signal should be inserted into PF22 via External Go port.
For information on External Go port, please refer to section 7.1.