5.5 List of functions
1. Volume
2. Tube dimension
20. Operator number
3. Velocity
21. Batch number
4. Acceleration/deceleration
24. Print status
5. Reversing (back suction)
29. Print parameters
6. Batch size
31. Save program
7. Delay
32. Load program
8. Completed fills
33. Delete program
9. Specific gravity
34. Print programs
10. Output rate
46. Set language
15. Input mode
47. Printer set-up
18. Timer 2
72. Volume format
19. Timer 3
80. Reset memory
5.6 Description of functions
The individual functions will be described in the following:
1. Volume
Value: Choice of ml and grams.
Range: Required volume from 1 to 9999.9 ml.
2. Tubes
Value: Inside diameter (i.d.) in mm
Range: 3.0 - 5.0 - 6.5 - 8.5 - 10.0 - 12.5
The tubes can be measured with the supplied tube gauge.
If the tube is changed, a new calibration must always be made.
3. Velocity
Value: Pump revolutions per minute (rpm)
Range: 30 - 250 rpm
If the velocity is changed, a recalibration should be made.
4. Acceleration/deceleration
Value: An integral number
Range: 1 - 100
The acceleration and the deceleration will always be the same. The lowest value (1) will give the
lowest acceleration, and the highest value (100) will give the fastest acceleration.