SPECIFICATIONS
71
11
SPECIFICATIONS
11.1
Pump head
11.1.1 Performance
Description
Bredel 265
Bredel 280
Bredel 2100
Max. capacity, continuous [m
3
/h]
40.0
56.0
72.0
Max. capacity, intermittent [m
3
/h]
*
*
Intermittent duty: Let the pump stand still to cool down for at least 1 hour after 2 hours of
operation.
64.4
78.2
108.0
Capacity per revolution [l/rev]
13.4
23.4
40.0
Max. permissible working pressure [kPa]
1600
Permissible ambient temperature [°C]
-20 to +45
Permissible product temperature [°C]
-10 to +80
Sound level on 1 m [dB(A)]
70