beautypg.com

Function 4 - acceleration/deceleration, Function 5 - reversing (back suction), Instruction handbook – Watson-Marlow PD12 IHS User Manual

Page 14

background image

INSTRUCTION HANDBOOK

PD12IHS / PD12IDH

PD12IHS_PD12IDH IH EN 74-115-181 v2.00.doc

Version: 2.00

Page 14 of 19

The fastest filling will be carried out at the highest velocity setting but the velocity should always be
adjusted to suit the characteristics of the product and to reduce splashing or foaming.


Function 4 - Acceleration/deceleration
Value: An integral number.

This function offers a choice of values between 1 and 200 dependent on the tube size and drive;
1 = slowest, 200 = fastest.

Tube Sizes

Max. Velocity

Max. acceleration

0.5 - 0.8 – 1.2 – 1.6

400

100

3.2

400

100

4.8 - 6.0 – 8.0

400

100



Function 5 - Reversing (back suction)
Value: An integral number.
After each filling the dispenser head can be set to perform a small back suction to prevent dripping.

The back suction can be set at values between 0 and 10.
0 = no back suction
10 = maximum back suction

The value has no relation to any other parameters and is solely a number of degrees of a rotor turn.
Consequently, the volume that is sucked back will depend on the tube diameter.


For other program possibilities; see the MC12 manual.