beautypg.com

5 mounting of silicone tubes, Mounting of silicone tubes, Instruction handbook – Watson-Marlow PD12 IHS User Manual

Page 11

background image

INSTRUCTION HANDBOOK

PD12IHS / PD12IDH

PD12IHS_PD12IDH IH EN 74-115-181 v2.00.doc

Version: 2.00

Page 11 of 19

4.5 Mounting of silicone tubes

PD12 is equipped with tube bridges and tube locks. The tube locks ensure that the mounted tubes do
not slide through the dispenser head when running.

The tube bridge retains the tube and performs the necessary pressure on the tubes.

Open the dispenser head by tipping each of the two locking pins up and lift the tube bridge

Figure 4-1 Removing the tube bridge

1

2

3

Mount the correct tube lock (1) on its dowel pin and place the tubes.

It is important that the tubes are situated in the two notches (2+3).

The Y-connector must be situated at the opposite side of the tube lock.
Now mount the tube bridge in its tracks and engage the two locking pins.

Figure 4-2 Mounting of silicone tubes

NB! Never leave the dispenser mounted with tubes overnight.
At least tip the locking pins up in order not to retain the tube in pressure.

This manual is related to the following products: