beautypg.com

Troubleshooting the masosine pump – Watson-Marlow MR-Series User Manual

Page 28

background image

Revision 1.4 / August 2013

Visit our website at

www.masosine.com

28

Troubleshooting the MasoSine Pump

Problem

Possible Causes

Remedy

Inadequate Flow

1. Incorrect shaft rotation


2. Scrapergate installation

3. Air leaks – external, internal

(loose fittings, lip seals)

1. (A) Check rotation

(B) Change wiring


2. Change Scrapergate & Guide

3. (A) Tighten fittings , i.e. Tri Clamp

(B) Replace worn lip seals or

o-rings

Loss of Performance

1. Worn Scrapergate

2. Scrapergate support of seal

housing worn where
scrapergate shuttles


3. Worn Liners

1. Check for wear & replace

2. Rotate to get a clean spot



3. Replace if worn

Leaks

1. O-rings (pinched, cut, missing)

2. Lip seals or seal housing

damages


3. Grooves in shaft sleeve from

abrasive applications or high
discharge pressure

1. Visual inspection – replace

2. Rebuilt or replace assembly

3A.Check system for discharge

pressure problems

3B.Consider hard coating shaftsleeve

Accelerated Wear

1. Speed or abrasion


2. Excessive discharge pressure

(>150 PSIG)



3. Dry Run

1. (A) Decrease pump speed

(B) Use larger pump


2. (A) Increase line size

(B) Check valves

(C) Check viscosity & line losses


3. (A) Recommend level control

(B) Change internals