Diagnostics

Verilink SCC 2130 User Manual

5-7

Front Panel LEDs

This section describes the function of the SCC 2130 LED indicators.

EQPT LED

The EQPT (equipment) LED is a tri-state indicator with six states, as
follows:

Table 5-3 Equipment LED States

STAT LED

The STAT (status) LED is a three-color indicator with six possible
states, as follows:

Table 5-4 Stat LED States

State

Meaning

Solid Green Typical, no DTE related alarms

Solid Yellow The SCC 2130 is in a loop which faces the Equipment port

(Repeater Loopback or Equipment Loopback)

Flashing

Red Twice,

To Green

LOS detection is enabled and the DTE is not asserting the lead

which the SCC 2130 is optioned to require; DTR (Data Terminal

Ready) or RTS (Request To Send)

Flashing

Red to Off

Hardware error, may indicate incorrect rear module is detected

Flashing

Red to

Yellow

The SCC is looped toward the equipment (RLB, ELB) and errors

are detected

Not Lit

The SCC has no power or, if other LEDS are lit, the SCC is

defective

State

Meaning

Solid Green This is invalid for the Stat LED

Solid

Yellow

A test is in progress and no errors are detected (a test signal is

currently being transmitted to the circuit by the CSU and the

received pattern matches the transmitted pattern)

Solid Red

Some alarm condition has occurred within the last fifteen

minutes on either the Network or Equipment interface

Flashing

Red to Off

Power up self test has failed — verify that the rear module is of a

correct type (CDM 2032, CDM 2132, CDM 2042, CDM 2142)

Flashing

Red to

Yellow

Errors have been received during a test (a test signal is being

transmitted and the pattern received does not match the pattern

which was sent)

Not Lit

No alarms have occurred within the last fifteen minutes, this is

the normal state for the Stat LED