Front panel leds, Eqpt led, Stat led – Verilink SCC 2130 (880-503282-001) Product Manual User Manual
Page 61

Diagnostics
Verilink SCC 2130 User Manual
5-7
Front Panel LEDs
This section describes the function of the SCC 2130 LED indicators.
EQPT LED
The EQPT (equipment) LED is a tri-state indicator with six states, as
follows:
Table 5-3 Equipment LED States
STAT LED
The STAT (status) LED is a three-color indicator with six possible
states, as follows:
Table 5-4 Stat LED States
State
Meaning
Solid Green Typical, no DTE related alarms
Solid Yellow The SCC 2130 is in a loop which faces the Equipment port
(Repeater Loopback or Equipment Loopback)
Flashing
Red Twice,
To Green
LOS detection is enabled and the DTE is not asserting the lead
which the SCC 2130 is optioned to require; DTR (Data Terminal
Ready) or RTS (Request To Send)
Flashing
Red to Off
Hardware error, may indicate incorrect rear module is detected
Flashing
Red to
Yellow
The SCC is looped toward the equipment (RLB, ELB) and errors
are detected
Not Lit
The SCC has no power or, if other LEDS are lit, the SCC is
defective
State
Meaning
Solid Green This is invalid for the Stat LED
Solid
Yellow
A test is in progress and no errors are detected (a test signal is
currently being transmitted to the circuit by the CSU and the
received pattern matches the transmitted pattern)
Solid Red
Some alarm condition has occurred within the last fifteen
minutes on either the Network or Equipment interface
Flashing
Red to Off
Power up self test has failed — verify that the rear module is of a
correct type (CDM 2032, CDM 2132, CDM 2042, CDM 2142)
Flashing
Red to
Yellow
Errors have been received during a test (a test signal is being
transmitted and the pattern received does not match the pattern
which was sent)
Not Lit
No alarms have occurred within the last fifteen minutes, this is
the normal state for the Stat LED