Maintenance reset – Verilink PRISM 4051 (34-00253.2) Product Manual User Manual
Page 44

38
C
HAPTER
4: T
ERMINAL
O
PERATION
If a password is programmed and later forgotten, contact Verilink Technical
support for a one-time backdoor password.
Store Parameters to EEPROM: This command causes the unit to store all
user-selectable parameters into non-volatile memory. These settings then become
the saved configuration which can be loaded at power-up.
This command causes the unit to restart and interrupts network traffic. Pressing Enter
on this field to activate the command brings up the following warning:
ARE YOU SURE? - THIS WILL
INTERRUPT DDS DATA
(NO!) (YES)
Maintenance Reset.
This field clears all user-selectable parameters, performance
registers, passwords, and alarms but saves the IP Address. All alarm threshold
parameters are set to default values. These settings are then written to non-volatile
memory as the saved configuration.
Pressing Enter on this field brings up the following warning:
DELETE ALL DATA AND
RESTART UNIT?
(NO!)
(YES)
To exit this screen without performing the reset function, press Enter with NO
selected. To proceed with the reset function, move the cursor to YES and press
Enter.
The reset operation sets all parameters to the factory default settings.
✍