Unit Configuration 9

SUPV Port Rate

Positions S2-5
and 2-6 set the
bit rate for the
network
management
system as shown
in Table 2-12.

NMS Port Rate

Positions S2-7
and 2-8 set the
bit rate for the
network
management
system as shown
in Table 2-13.

Configuration

Switch S3

Switch S3
(Figure 2-4) is
reserved for
future expansion,
with the
exception of
S3-8, which is
used to force
download mode.

Force Download Mode

Switch S3-8 is used to Force
Download Mode as shown in
Table 2-14. For download bit-rate
information refer to step 7 of
PC Setup on page 39.

Address Switch S4

Switch S4 sets the unit
address. When using the

4051 with an 8100A Site

Controller, each element in a
group must have a unique
unit address. As many as 50
units (with addresses from 1
to 50) can exist in a group.
If the unit is not connected to a site controller, the NMS unit address should be left
at the factory default setting of 1 where Position 1 is Up and all other positions are
Down (see Figure 2-5).

Table 2-12 SUPV Port Rate

NMS Port Rate

S2-5

S2-6

19.2 kbps

Down

Down

1.2 kbps

Down

Up

2.4 kbps

Up

Down

9.6 kbps

Up

Up

Table 2-13 NMS Port Rate

NMS Port Rate

S2-7

S2-8

19.2 kbps

Down

Down

1.2 kbps

Down

Up

2.4 kbps

Up

Down

9.6 kbps

Up

Up

Figure 2-4 Switch S3

7

6

5

4

3

2

1

Do

wn

Up

8

Un

u

se

d

Un

u

se

d

Un

u

se

d

Un

u

se

d

F

o

rc

e Do

wn

lo

a

d

Mo

d

e

Un

u

se

d

Un

u

se

d

Un

u

se

d

Switch

S3

Table 2-14 Force Download Mode

Mode

S3-8

Normal Operation

Down

Begin Flash Download

Up

LSB

MSB

Binary values

1

2

4

8

16

32

64

128

0

0

0

0

0

0

0

0

Figure 2-5 Switch S4

7

6

5

4

3

2

1

Do

wn

Up

8

Switch

S4