Data port connections – Verilink PRISM 4051 (34-00253.2) Product Manual User Manual
Page 18

12
C
HAPTER
2: I
NSTALLATION
The NMS address, port rate, and power
up configuration mode may be set by
either configuration switches or
through software control. The physical
connection is 6-pin modular connector
with the pinouts for these connectors
shown in Table 2-16. This port is a
serial RS-232 DCE port configured for
eight bits, no parity, and one stop bit.
Data Port
Connections
Both models of the
Verilink 1051 chassis
provide connection to the
customer equipment. Each
slot of the 1051-2 has a
corresponding DTE 8-pin
RJ-48 connector and a
high-speed DTE female
25-pin connector located
on the chassis rear panel.
The 1051-3 chassis is
similar except that it has a
high-speed DTE 34-pin
connector instead of the
25-pin connector. The
pinout for the DTE RJ-48
connector is given in
Table 2-17 and the pinout
for the high-speed DTE
connectors is given in
Table 2-18.
FCC rules require that interconnecting cables carrying high-speed data be shielded
appropriately to minimize radio frequency interference.
Table 2-16 NMS Port Connector Pinouts
Pin
NMS Bus IN
NMS Bus OUT
1
Not Used
Not Used
2
Signal Ground
Signal Ground
3
Data Out
Data Out
4
Data In
Not Used
5
Signal Ground
Signal Ground
6
Not Used
Not Used
Table 2-17 DTE RJ-48 Pinout
Pin
Signal
1
Data Out
2
Data Out
3
Not Used
4
Data In
5
Data In
6
Not Used
7, 8
Chassis Ground
Table 2-18 High-Speed DTE Connector Pinout
ITU/EIA
Circuit
Common Name
DB-25
25-pin
V.35
34-pin
DCE
101/AA
Frame Ground
1
A
Gnd
102/AB
Signal Ground
7
B
Gnd
103/BA (A)
Transmit Data A
2
P
In
103/BA (B)
Transmit Data B
14
S
In
104/BB (A)
Receive Data A
3
R
Out
104/BB (B)
Receive Data B
16
T
Out
105/CA
Request to Send
4
C
In
106/CB
Clear to Send
5
D
Out
107/CC
Data Set Ready
6
E
Out
108/CD
Data Term Ready
20
H
In
109/CF
Data Carrier
Detect
8
F
Out
114/DB (A) Transmit Clock A
15
Y
Out
114/DB (B)
Transmit Clock B
12
AA
Out
115/DD (A) Receive Clock A
17
V
Out
115/DD (B) Receive Clock B
9
X
Out
113/DA (A) External Clock A
24
U
In
113/DA (B)
External Clock B
11
W
In
141/LLB
Local Loopback
18
J
In
140/RLB
Remote Loopback
21
BB
In
142/TM
Test Mode
25
K
Out