Managementports, Figure 4-14 management ports, Coa connection (supv) – Verilink PRISM 4001 (34-00244) Product Manual User Manual
Page 30: Primary dial string, secondary dial string, Initialization string, Disconnection string, Management ports -10, Management ports

4-10 Terminal Operation
PRISM 4001
Management Ports
The Management Ports screen (Figure 4-12) sets the follow-
ing parameters for the S
UPV
port.
COA C
ONNECTION
(S
UPV
)
Controls remote alarm reporting. ASCII alarm reporting
through the supervisory port is independent of Trap alarm
reporting which is done by the Site Controller 8100A. The
ASCII alarm report type is set by the following choices:
DISABLED: Alarm reporting is disabled.
DIRECT: Sends reports to a printer or terminal connected
directly to the S
UPV
port.
DIAL: Sends reports through an attached AT command set
compatible modem connected to the S
UPV
serial port, which
must dial out to a remote modem. The message format is
described in the ELEMENT ID field.
P
RIMARY
D
IAL
S
TRING
, S
ECONDARY
D
IAL
S
TRING
ASCII strings for the primary and secondary call on alarm
numbers used in the [DIAL] mode. The strings must include
the ATDT command prefix. The 4001 makes three attempts
to connect using the primary number. If all three attempts
fail, it makes three attempts three to connect using the sec-
ondary number (if it is not blank). If the secondary number
fails, the 4001 waits five minutes and then attempts to com-
municate with the primary number again. When a connection
is detected, the 4001 outputs the notification message (as
described in the ELEMENT ID field) and then disconnects.
I
NITIALIZATION
S
TRING
The modem initialization string is entered in this field.
Refer to the modem’s documentation for further informa-
tion. The default setting is ATEQ0V1S0=1.
D
ISCONNECTION
S
TRING
Identifies the character string to be output when the modem
session is terminated. The default setting is ATH0.
4001 DSU x.xx/x.xx
PRISM 4001 Local
Screen
4001 DSU x.xx/x.xx
Unit Address: X
--------------------------- Management Ports ----------------------------
--------------------------- Supervisory Port ----------------------------
COA Connection:
[DISABLED ]
Primary Dial String:
(
)
Secondary Dial String:
(
)
Initialization String:
(ATEQ0V1S0=1
)
Disconnection String:
(ATH
)
------------------------------- Messages
--------------------------------
Figure 4 -14 Management Ports