Prism 3301 mib, T3nettable – Verilink PRISM 3301 (34-00239.5) Product Manual User Manual
Page 42
34
A
PPENDIX
A: MIB R
EFERENCE
PRISM
3301 MIB
{ 1.3.6.1.4.1.425.2.8.1 } The PRISM 3301 proprietary MIB contains the Network,
DTE, Current (current TR 54014 Performance Monitoring data), Interval (TR
54014 Performance Monitoring 15-Minute Intervals), and Total (TR 54014
Performance Monitoring 24-Hour Totals) tables.
t3NetTable
{ 1.3.6.1.4.1.425.2.8.1.1 } This table defines the PRISM 3301 Datalink
Configuration, Status, and Control Objects.
Object Name
Object ID
User Access Object Description
t3NetIndex
t3NetConfigEntry 1
read-only
The value for this object is equal to the value of IfIndex from the Interfaces
table of MIB II (RFC 1213).
t3NetLBO
t3NetConfigEntry 2
read-write
Line buildout level for DS3 interface.
1 - lbo_0
2 - lbo_150
3 - lbo_300
t3NetYellowXBit t3NetConfigEntry 3
read-write
Representation of the yellow alarm.
1 - off
2 - on
t3NetAISPattern
t3NetConfigEntry 4
read-write
AIS can be represented in two forms. One is the standard DS3 blue alarm
with alternate 1's and 0's such as 1010...., and the other is all 1's used by
MCI. The default is blue.
1 - blue
2 - FAO
t3NetAISRxStuff
t3NetConfigEntry 5
read-write
Controls the AIS Rx-Stuffing option.
1 - off
2 - on
t3AISTxXBit
t3NetConfigEntry 6
read-only
Controls the value of the X-bit when transmitting AIS.
1 - zero
2 - one
t3Map
t3NetConfigEntry 7
read-write
This object is bit mapped. Set bits to select active timeslots as follows:
1 - Timeslot 1
2 - Timeslot 2
4 - Timeslot 3
8 - Timeslot 4
16 - Timeslot 5
32 - Timeslot 6
64 - Timeslot 7
128 - (RESERVED, must be 1)
Multiple bits can be set at the same time. Default all bits are set.
t3Scrambler
t3NetConfigEntry 8
read-write
Enable/Disable scrambler. The scrambler can be set for either 7 or 10 bit
scrambling. The default is off.
1 - off
2 - bit-7
3 - bit-10
t3Dsu
t3NetConfigEntry 9
read-write
The PRISM 3301 has the capability to route the incoming T3 signal to a
pair of AUX BNC connectors instead of to the DTE port. The values mean:
1 - Primary - The T3 signal path is to/from the DTE port. The AUX BNC
connectors are inactive.
2 - Secondary - The T3 signal path is to/from the AUX BNC connectors.
The DTE port is inactive.
t3NetLoopback
t3NetConfigEntry 10
read-write
This variable expands upon RFC1407 variable dsx3LoopbackConfig.
1 - dsx3NoLoop
3 - dsx3LineLoop
5 - dsx3FarProprietaryLoop - The unit at the other end was put into LINE
loop by this unit using a proprietary C-bit message.
t3NetStatus
t3NetConfigEntry 11
read-only
This variable expands upon RFC1407 variable dsx3LineStatus.
1024 - t3BPV
2048 - t3Parity
4096 - t3RemoteParity
8192 - t3Other