Dsx3farendconfig – Verilink PRISM 3301 (34-00239.5) Product Manual User Manual
Page 40

32
A
PPENDIX
A: MIB R
EFERENCE
dsx3FarEndConfig
{ 1.3.6.1.2.1.10.18.9 } The DS3 Far End Configuration Table contains
configuration information reported in the C-bits from the remote end.
Implementation of this table is optional for all systems that attach to a DS3
Interface. However, only C-bit Parity and SYNTRAN DS3 applications have the
capability (option) of providing this information.
Object Name
Object ID
User Access Object Description
Get
dsx3FarEndLineIndex
dsx3FarEnd Entry 1 read-only
The index value which uniquely identifies the
DS3 interface to which this entry is applicable.
The interface identified by a particular value of
this index is the same interface as identified by
the same value an dsx3LineIndex object
instance.
dsx3FarEndEquipCode
dsx3FarEndEntry 2 read-only
This is the Far End Equipment Identification
code that describes the specific piece of
equipment. It is sent within the Path
Identification Message.
Returns the Far
End Equipment
Identification code.
dsx3FarEndLocationIDCode dsx3FarEndEntry 3 read-write
This is the Far End Location Identification code
that describes the specific location of the
equipment. It is sent within the Path
Identification Message.
Returns the Far
End Location
Identification code.
dsx3FarEndFrameIDCode
dsx3FarEndEntry 4 read-write
This is the Far End Frame Identification code
that identifies where the equipment is located
within a building at a given location. It is sent
within the Path Identification Message.
Returns the Far
End Frame
Identification code.
dsx3FarEndUnitCode
dsx3FarEndEntry 5 read-write
This is the Far End code that identifies the
equipment location within a bay. It is sent
within the Path Identification Message.
Returns the Far
End Unit code.
dsx3FarEndFacilityIDCode
dsx3FarEndEntry 6 read-write
This code identifies a specific Far End DS3
path. It is sent within the Path Identification
Message.
Returns the Far
End Facility ID
code.