Test loop remote clear, Test loop remote request, Test loop remote end – Verilink PRISM 3301 (34-00239.5) Product Manual User Manual
Page 35: Test system, Reset commands, Reset alarms, Reset performance, Reboot commands, Reset alarms reset performance

Configuration Commands
27
TEST LOOP REMOTE CLEAR
This command clears the remote loopback test.
TEST LOOP REMOTE REQUEST
This command sends a pattern to the remote PRISM 3301 requesting it perform a
remote line loopback. When the remote PRISM 3301 unit detects the loop request,
it loops the network receive data back to the transmitting end after passing through
the DS3 analog receiver circuit, as shown in Figure 4-5.
Figure 4-5 Remote Line Loopback
This loopback can be initialized by either the local or far-end unit using either user
interface. When initiated at the local end, the loop code must be transmitted to the
far end. During the loop test, all 1s are transmitted to the remote DTE from the
remote PRISM 3301.
TEST LOOP REMOTE END
This command sends a pattern to the remote PRISM 3301 ending the remote line
loopback.
TEST SYSTEM
This command reports the results of an on-going (background) system tests on the
unit. The tests respond with a pass or fail report for the CODE EPROM and the
NVRAM.
Reset Commands
The RESET commands are associated with the performance monitoring of the
PRISM 3301 by resetting the unit alarm and performance data. Each command is
followed by one or more keywords with each keyword being separated by a space.
RESET ALARMS
This command clears the alarm queue and the unit restarts the alarm accumulation.
Alarm history is lost. User confirmation is required for this command.
RESET PERFORMANCE
This command resets the performance monitoring data base. There must be a user
confirmation to execute this command.
Reboot Commands
The REBOOT commands perform a warm or cold boot. Each command is
followed by one or more keywords with each keyword being separated by a space.
DTE
DTE
Remote 3301
Local 3301