37

Multifunctional settings

Item

Description

SERVICE

Selecting this item displays the SERVICE menu.

Select an item using the buttons ▲/▼, and press the button ► or

the ENTER button on the remote control to execute the item.

FAN SPEED  AUTO ADJUST  GHOST  KEY LOCK  FILTER MESSAG  FACTORY RESET

FAN SPEED

Using the buttons ▲/▼ switches the rotation speed of the cooling

fans. The HIGH is the mode for use at highlands etc. Note that the

projector is noisier when the HIGH is selected.

HIGH  NORMAL

AUTO ADJUST

Using the buttons ▲/▼ enables/disables the automatic adjustment.

When DISABLE is selected, the automatic adjustment feature is

disabled, although rough adjustment is automatically performed

depending on the basic setting.

ENABLE  DISABLE

• Depending on conditions, such as input image, signal cable to the

projector, environment around the projector, etc., the automatic adjustment

may not work correctly. In such a case, please choose DISABLE to

disable the automatic adjustment, and make adjustment manually.

GHOST

1. Select a color element of ghost using the buttons ◄/►.

2. Adjust the selected element using the buttons ▲/▼ to disappear ghost.

2.

2.
KEY LOCK

Using the buttons ▲/▼ turns on/off the key lock feature. When TURN ON is

selected, the buttons on the projector except the STANDBY/ON button are locked.

TURN ON  TURN OFF

• Please use to avoid a mischief and touching accidentally. This

function does not have any effect on the remote control.

FILTER MESSAGE

Use the ▲/▼ button to set the timer for the interval to show the

message for cleaning up the air fi lter.

100h  200h  300h  TURN OFF  50h

After selecting “50h”, 100h”, “200h”, or “300” , the message “CLEAN

THE AIR FILTER” will appear after the timer reaches the interval

time set by the menu. Please refer to the “FILTER TIME” item (

36) and the table “Related message” (

42)

When the “TURN OFF” is chosen, the air-fi lter cleaning message will not appear.

• Please check and clean the air fi lter periodically, even if there is

no message. If the air fi lter becomes blocked by dust or others, the

internal temperature will rise, which could cause malfunction, or

reduce the lifetime of the projector.

• It is recommended to choose “100h” in general. Please be careful

with the operating environment of the projector and the condition of air

fi lter, especially when the “200h”, “300h” or “TURN OFF” is chosen.

FACTORY RESET

Selecting RESET using the button ▲ performs this function. By this function,

all the items in all of menus will collectively return to the initial setting. Note

that the items LAMP TIME, FILTER TIME and LANGUAGE are not reset.

RESET  CANCEL