SPECIFICATIONS

DC Volts

Ranges:

0-3, 15, 60, 300 (20,000 ohms per volt)

Accuracy:

±3% of full scale value

AC Volts

Ranges:

0-3, 15, 60, 300 (5,000 ohms per volt)

Accuracy:

±4% of full scale value
(on 60Hz sine wave at 77° F)

Ohms

Ranges:

0-20K, 200K, 2 Meg, 20 Meg
(200, 2K, 20K, 200K @ center scale)

Accuracy:

±3% of DC scale length
(with fully charged battery)

Ohmmeter Specifications:

Range

X1 X10 X100 X1K

Max Voltage
(Volts)

1.6 1.6 1.6 14.0

Max Current
(mA)

8.0 0.8 .08 .07

Max. Power
(mW)

3.2 .32 .032 .245

DC Milliamperes

Ranges:

0-.6, 6, 60, 600

Accuracy:

±3% of full scale value

Burden Voltage (@ full scale):

Approx. 330mV on 600mA range
Approx. 250mV on other ranges